Sievers M9 On-Line TOC Analyzer
The Sievers M9 On-Line Analyzer offers excellent low-level sensitivity for ultrapure water analysis and high-level capability for cleaning validation or other challenging water samples. It’s proprietary Integrated On-Line Sampling (iOS) System enables easy introduction of external standards and samples without removing the instrument from the continuous sample source. With Sievers unique technology, the M9 On-Line is immune to false positive and false negatives that trouble non-membrane based TOC instruments.
Explore how to increase productivity with continuous monitoring
Designed for continuous monitoring of waters from ultrapure to potable, the M9 On-Line provides unparalleled accuracy, precision, and speed across a dynamic operating range of 0.03 ppb to 50 ppm. It supports compliance with pharmacopeia water testing or can be used for cleaning validation and other online applications. In Turbo mode, the M9 provides analysis every four-seconds, providing up-to-the-second results for better control. Sievers M9 Analyzers meet or exceed the most common pharmaceutical regulatory requirements for TOC analysis and data integrity.
M9 On-Line Features & Benefits
- Two-minute sample analysis time
- Continuous monitoring with the ability to easily introduce discrete grab samples and standards
- Wall-mounted with an IP-45 rated enclosure to withstand demanding environments
- Automated operations, such as calibration and data analysis
- Autoreagent feature automatically establishes optimal flow rates for each sample
- Minimal preventive maintenance (typically just a few hours per year)
- 12-month calibration stability
- Optional Turbo mode for four-second analysis
M9 On-Line Specifications
Operating Specifications* |
|
---|---|
Range | 0.03 ppb to 50 ppm |
Precision | < 1% RSD |
Accuracy | ± 2% or ± 0.5 ppb, whichever is greater |
Display Readout | 3 significant digits |
Sample Type | On-line continuous or discrete grab sample |
Calibration | Typically stable for 12 months |
Analysis Time | 2 minutes (4 seconds with the optional Turbo mode) |
Sample Temperature** | 5–95 °C (41–203 °F) |
Ambient Temperature | 5–40 °C (41–104 °F) |
Sample Pressure | 100 psig |
On-Line Flow Rate | >50 mL/min (for on-line mode) |
Instrument Sample Flow Rate |
0.5 mL/min |
Analyzer Specifications |
|
Outputs | 4-20 mA outputs (3); alarm outputs (4); binary input (1); USB device port (1); USB host ports (2); Modbus TCP/IP |
Display | 7″ WVGA 800X480 pixel, Color LCD with touch-screen |
Power | 100 – 240 V~, 50 -60 Hz, 100 VA |
Fuses | Replace with same type and size fuse: T 1.6 A 250 VAC Fuse (Slow Blow), size 5 X 20 mm appliance inlet |
Dimensions | H: 54.9 cm (21.6 in); W: 45.0 cm (17.7 in); D: 26.5 cm (10.4 in) |
Weight | 15.8 kg (34.9 lb) |
Enclosure Rating | IP-45 |
Safety Certifications | ETL, CE (see Declaration of Conformity) |
Environment |
|
Maximum Relative Humidity | 0 – 95%, non-condensing |
Maximum Altitude | 3,000 m (9.800 ft) |
Pollution Degree | 2 |
M9 On-Line Turbo Specifications
Operating Specifications* |
|
---|---|
Range | 0.20 ppb to 10 ppm |
Precision | 2% RSD |
Accuracy | ± 10% or ±10 ppb whichever is greater |
Display Readout | 3 significant digits |
Sample Type | On-line, Grab |
Calibration | Typically stable for 12 months |
Analysis Time | 4 seconds |
Response Time | 3.25 minutes |
Sample Temperature | 5–95 °C (41–203 °F) |
Ambient Temperature | 10–40 °C (50–104 °F) |
Sample Pressure | 100 psi |
Sample Flow Rate | 30–300 mL/min (for on-line mode) |
Instrument Sample Flow Rate |
1.1 mL/min |
Analyzer Specifications |
|
Outputs | 4-20 mA outputs (3); alarm outputs (4); binary input (1); USB device port (1), USB host ports (2); Ethernet (1) |
Display | 7” WVGA 800×480 pixel, Color LCD w/touch-screen |
Power | Universal Power Supply: 100–240 ± 10% VAC, 50 W, 50/60 Hz |
Dimensions | H: 54.9 cm (21.6 in); W: 45.0 cm (17.7 in); D: 26.5 cm (10.4 in) |
Weight | 15.8 kg (34.9 lb) |
Safety Certifications | ETL, CE |
Enclosure Rating | IP-45 |
Consumables |
|
UV Lamp | 6 months |
Acid Reagent | As needed, typically 6 months |
Oxidizer Reagent | As needed, typically 3-month stability |
*Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.
M9 On-Line Options & Accessories
- Inorganic Carbon Remover (ICR): Improves TOC accuracy for samples with high inorganic carbon levels
- Turbo Mode: Provides four-second analysis time
- DataGuard Software: Full compliance support for 21 CFR Part 11 and Annex 11
Comparing Online TOC Analyzers and Sensors
TOC analyzers using the Membrane Conductometric method (such as the M9 On-Line Analyzer) are more accurate than sensors and should be applied to critical quality decisions involving regulatory reporting, measuring product quality, real-time release, managing process control limits, and performing system validation.
Cleaning Validation (Lab, At-Line, and On-Line) with Sievers M9 TOC Analyzers
Not sure which analyzer you need for cleaning validation? This document compares the M9 Lab, Portable, and On-Line to help you select the right analyzer for your application.
21 CFR Part 11 with the Sievers M9 and DataPro2 Software
Sievers M9 Analyzers are compliant with 21 CFR Part 11. Our DataPro2 and Dataguard software are designed for the pharmaceutical industry to offer complete solutions for electronic signatures and audit trails.